Troubleshooting Your Furnace: Why It Keeps Turning On and Off

Since our establishment in 2001, we’ve proudly served Aurora, IL, as the go-to experts for all heating and cooling needs. At Maximum, we believe in transparency and reliability, so we offer upfront pricing with a no-surprise price guarantee, along with free estimates for our valued customers.

If you’ve ever found yourself puzzled by your furnace kicking on only to shut off unexpectedly, you’re not alone. This frustrating scenario can leave homeowners scratching their heads for answers. But fret not! In this blog, we’ll delve into the intricacies of furnace operation and provide you with expert insights and troubleshooting tips to try before seeking professional assistance. From upfront pricing to free estimates, Maximum Heating & Air Conditioning ensures your home stays comfortable, and your furnace operates at its maximum potential. Let’s unlock the secrets of your furnace together!

AC service and furnace repair van in aurora, il

A typical furnace will run three to eight heating cycles every hour; on average, these cycles will last 5 to 15 minutes. These cycles will vary depending on things like the temperature outside, the size of your home, the type of furnace, insulation, etc. If your furnace is turning on and turning back off after just a few minutes or starts more than eight times an hour, this is referred to as short cycling and is something you definitely don’t want to ignore. If left uncorrected, this will cause your furnace to struggle to heat your home, increase your energy bills, and put unnecessary stress on your system.

furnace in Aurora basement

Let’s dive into the 11 common reasons your furnace is turning on and back off shortly after.

  1. The first common reason your furnace turns on and back off quickly is a lack of airflow that a dirty air filter can cause. When there is not adequate airflow through the system, the heat exchanger will frequently heat up and turn off when it has reached its maximum temperature, causing your furnace to turn off. If you haven’t recently changed your air filter, do a visual inspection and change if necessary. The air filter traps dirt, dust, and other debris and can block the airflow through your system if not routinely changed. Replacement every 90 days is the recommendation for a household free of allergies or pets and 60 days (or less) for households with pets or allergies.

    Dirty filter coming out of a broken furnace

  1. The next thing to check to ensure that your furnace doesn’t turn off for lack of airflow is your vents. You might have closed some of the vents in the past and forgotten to re-open them. You will also want to visually inspect the vents to ensure there are no foreign objects or debris blocking the airflow through the vents. It’s always best to keep all vents open to prevent any damage to your system from overheating. If you think there may be damage to your system, don’t hesitate to contact the experts at Maximum – we’re always happy to help! Give us a call at (630)788-4688.

  1. A dirty blower wheel is another likely culprit for your furnace turning on and back off too quickly due to airflow issues. The blower wheel has blades that are designed to push the air from your furnace to the vents. If these blades become dirty, it won’t work as efficiently or sometimes at all. Routinely changing your air filters will ensure that dirt doesn’t build up on these blades. One of our licensed technicians would happily help you with this repair – https://www.aurorailhvacservice.com/request-estimate/

  1. If your furnace is still turning on and quickly back off, your thermostat is the next place to check. A furnace turning on and back off too quickly can be a sign of a malfunctioning or broken thermostat. Several things can cause your thermostat not to work properly. If your thermostat needs new batteries, it will often malfunction. It’s also a good idea to do an inspection of the wiring to your thermostat to make sure they are not old and needs replacement. Lastly, a thermostat that has been placed too close to a heat source (like direct sunlight or a heat register) can skew the temperature reading and cause the thermostat to turn on and off irregularly. If you are concerned about old wiring or would like to relocate your thermostat, call Maximum at (630)788-4688, and we’ll send out an HVAC technician to get you taken care of.

    best furnace brands 2023

  1. A dirty or broken flame sensor is the next likely culprit for your furnace’s short cycling. The flame sensor is in place to detect the flame and signal the gas valve to open. If there is no flame or if the sensor is malfunctioning, it is a safety feature that will turn off the gas valve to keep gas from leaking into the house. The system will shut down and restart when this gas valve turns off. You can access and try to clean off the flame sensor or call in the professionals at Maximum if you don’t feel comfortable or if you think the sensor needs replaced. Call us anytime at (630)788-4688. First, make sure you turn off the gas to the furnace and then remove the front panel where you will find the ignitor or ignition sensor near the burners. If the sensor or ignitor is dirty, you can remove it carefully with a screwdriver and gently clean it – be careful not to break it. Once cleaned, replace it back how you found it, put the front panel back on, turn on the gas, and then turn your furnace on.

  1. Another possible cause of your furnace turning on and off quickly is an issue with your furnace blower motor. The purpose of the furnace blower motor is to circulate the warm air throughout your house. It’s rare for the system to run still when the blower motor is off, but it can happen, and this would cause your furnace to short cycle. When the furnace is running, check to see if air is coming out of your vents. If there is no air or minimal air coming out of the vents, you likely have an issue with your furnace blower motor. Routine system maintenance can ensure that these parts of your furnace are properly maintained and will minimize issues such as this. We offer our Maximum Service Plan for affordable twice-yearly maintenance to keep your system running efficiently – https://www.aurorailhvacservice.com/maintenance-program/

    furnace in Aurora basement

  1. Another thing to check if your furnace is short cycling is your flue pipe, otherwise known as your exhaust vent, which can be found on your roof. Debris, such as dirt, sticks, leaves, or a bird nest, could be blocking the vent. If this becomes blocked, it will cause hot gases to build up in your furnace, causing it to overheat. Your furnace is equipped with another safety feature that will shut your furnace down if it is overheating. Checking to make sure there are no obstructions to your flue pipe routinely is a great way to avoid these potential issues.
  1. A faulty pressure switch is another common cause of your furnace turning on and back off after a few minutes. The pressure switch is in place to close with the airflow from the draft inducer motor through the burner to indicate that combustion is safe. If your switch is defective, it will not let the system know that ignition is safe to continue. If this happens, the ignition will be paused after just a few minutes, and the furnace will then turn off. If you have a multimeter, it can help you determine if there is an issue with your pressure switch.

  1. Like the pressure switch, the inducer motor is another part of your furnace that can become faulty and cause your furnace to turn off after just a few minutes. The draft inducer motor draws air into the burner and pushes it out the flue, as well as bringing in enough air to allow the pressure switch to close and activate the ignition process. If this part becomes defective, it won’t let the pressure switch close to ignite the furnace, and it will ultimately shut the furnace off after a few minutes.

  1. Believe it or not, you can have too big of a unit for the size of your home, which can cause your furnace to short cycle. When the unit is too big for your house, it will heat your house too quickly and then turn off abruptly. When your home becomes cool again, the cycle will repeat. In this instance, the only resolution to this problem is to replace the unit with one that is appropriately sized for your home. If you need a new, properly sized system, call the experts at Maximum Heating & Air Conditioning at (630)788-4688. We take the time to ask questions about your needs and are expertly trained to ensure we help you select the best unit for you. We offer a variety of financing options and can find a payment plan that works for your budget – https://www.aurorailhvacservice.com/financing-options/

  1. There are a handful of other reasons that your furnace might be turning back off just minutes after it’s turned on that will require a call to the professionals at Maximum. Our HVAC technicians undergo continuous training to diagnose and quickly fix any issue that may arise with your furnace, so call us today to get you back up and running – (630)788-4688!
    • Control board failure
    • Overheating heat exchanger
    • Damaged fan limit switch
    • Rust or corrosion to the system due to water damage

price guarantee

As we bring this blog to a close, we extend our sincere appreciation to you for joining us on this journey of furnace exploration and troubleshooting. At Maximum Heating & Air Conditioning, our commitment to providing top-notch service and transparency has guided us since our inception in 2001.

We’re grateful for the opportunity to serve the Aurora, IL community and beyond, offering upfront pricing with a no-surprise price guarantee, along with free estimates to ensure your peace of mind. Whether you’ve successfully resolved your furnace issues with our expert insights or still have questions, know that our team is here to support you every step of the way. Give us a call anytime at (630)788-4688. From all of us at Maximum, thank you for allowing us to be a part of keeping your home comfortable and cozy. Until next time, stay warm, Aurora!